LaGard 700 Series Programming Instructions
Step-by-step programming instructions for the dormakaba LaGard 700 Series electronic safe locks — Models 701, 702, 702D, 703, and 705. Includes both display keypad menu navigation and non-display # command methods for changing combinations, adding and deleting users, and master reset procedures.
About the LaGard 700 Series
The LaGard 700 Series is dormakaba's current-generation electronic safe lock platform, replacing the legacy LaGard Basic, ComboGard Pro 39E, 66E, and Supra models. All 700 Series locks use the same lock body — the keypad model determines the feature level. The 701 is the entry-level (replaces the Basic), the 702 replaces the 39E/66E/Supra, and the 703/705 are high-security multi-lock models for commercial and vault applications.
The 700 Series uses a User ID + Combination system instead of the old "hold down last digit" method. Programming is done through # commands on non-display keypads or through the on-screen menu on display keypads (702D, 703, 705).
Model Comparison
| Feature | 701 | 702 | 703 | 705 |
| Display Option | No | With or Without | Yes (OLED) | Yes (OLED) |
| Total Users | 3 | 10 | 30 | 99 |
| Locks Supported | 1 | 1 | 2 | 5 |
| Dual User Mode | No | Yes | Yes | Yes |
| Time Delay | No | 0–99 min | 0–99 min | 0–99 min |
| Audit Trail | No | 500 events | 500 events | 6,000 events |
| Timelock/Schedules | No | No | No | Yes |
| Bluetooth Fob | No | No | No | Yes |
| Replaces Legacy | Basic | 39E / 66E / Supra | Supra+ | SmartLinc II |
Select Your Model for Programming Instructions
| Model | LaGard 701 — Entry-level (replaces LaGard Basic) |
| Display | No display — uses # commands only |
| Factory Default | User ID 00 · Combination 1-2-3-4-5-6 |
| Code Length | 6–9 digits (configurable) |
| Users | 3 total — 1 Master (ID 00) + 1 Manager (ID 01) + 1 User |
| Locks | 1 lock body |
| Power | Two 9V alkaline batteries |
| Penalty | 5-minute lockout after 4 wrong attempts |
Open the Safe
- Press any key to wake the keypad — the backlight turns on (if enabled).
- Enter your User ID (factory Master ID is 00).
- Enter your combination (factory default: 1-2-3-4-5-6).
- Listen for 3 beeps + green LED flash = valid code. Turn the handle within 4 seconds.
Change Your Combination
ALWAYS perform this with the safe door OPEN.
- Press #52 on the keypad.
- Enter your User ID + current combination.
- Enter your User ID + new combination.
- Enter your User ID + new combination again to confirm.
- Press the Return Key (←).
- 3 beeps + green LED = success.
Example: Master (ID 00) changing from 1-2-3-4-5-6 to 6-5-4-3-2-1:
Add a New User (Master Only)
- Press #54 on the keypad.
- Enter 00 + Master combination.
- Enter the new User ID + initial combination.
- Re-enter the new User ID + initial combination to confirm.
- Press the Return Key (←).
Delete a User (Master Only)
- Press #56 on the keypad.
- Enter 00 + Master combination.
- Enter the User ID to delete.
- Press the Return Key (←).
Master Reset (Factory Reset)
- Press #58 on the keypad.
- Enter 00 + Master combination.
- Press the Return Key (←).
- 3 beeps + green LED = lock is reset to factory defaults.
# Command Quick Reference — 701
| Command | Function |
| #52 | Change your own combination |
| #54 | Add a new user |
| #56 | Delete a user |
| #58 | Master reset (factory reset) |
| #42 | Buzzer On/Off (0=Off, 1=On) |
| #44 | Combo length (6–9 digits) |
| Model | LaGard 702 — Mid-range (replaces 39E / 66E / Supra) |
| Display | 702: No display (# commands) · 702D: OLED display (menu + # commands) |
| Factory Default | User ID 00 · Combination 1-2-3-4-5-6 |
| Code Length | 6–9 digits (configurable) |
| Users | 10 total — 1 Master (ID 00) + 1 Manager (ID 01) + 8 Users |
| Locks | 1 lock body |
| Dual User Mode | Yes — requires 2 authorized users to open |
| Time Delay | 0–99 minutes (with 1–60 minute confirmation window) |
| Audit | 500 events (downloadable via USB on display model) |
| Power | Two 9V alkaline batteries |
| Penalty | 5-minute lockout after 4 wrong attempts |
⚡ 702 comes in two versions — pick your keypad type:
702 (no display): Uses # commands — same method as the 701 above.
702D (with display): Uses on-screen menus — follow the display instructions below.
702D — Display Keypad Instructions
Open the Safe (Display)
- Press any key to wake the keypad — the OLED display illuminates.
- Enter your User ID (factory Master ID is 00).
- Enter your combination (factory default: 1-2-3-4-5-6).
- The screen shows "Open" — turn the handle within 4 seconds.
Change Your Combination (Display)
ALWAYS perform this with the safe door OPEN.
- Enter your User ID and current combination to log in.
- From the Main Menu, select "Change Combo".
- "New Combo" appears — enter your new combination.
- Re-enter the new combination to confirm.
- "Success" appears on screen + 3 beeps + green LED.
Add a New User (Display — Master Only)
- Log in with Master ID (00) and Master combination.
- Navigate to Main Menu → Users → Add.
- Enter the User ID to assign (e.g., 02, 03, etc.).
- Enter an initial combination for the new user.
- Set the user's privileges (Open, Audit, Time Delay Override).
- 3 beeps + green LED confirms.
Delete a User (Display — Master Only)
- Log in with Master ID (00) and Master combination.
- Navigate to Main Menu → Users → Delete.
- Enter the User ID to delete. Confirm when prompted.
Enable/Disable Dual User Mode (Display)
- Log in as Master.
- Navigate to Main Menu → System → User Mode.
- Select Single (normal), Dual (requires 2 users), or Dual + Mgr (dual with manager override).
Master Reset (Display)
- Log in with Master ID (00) and Master combination.
- Navigate to Main Menu → Locks → Reset.
- Select the lock and confirm.
- "Success" appears — lock reverts to factory defaults.
702 — Non-Display Keypad Instructions
Open the Safe (Non-Display)
- Press any key to wake the keypad.
- Enter your User ID (factory Master ID is 00).
- Enter your combination (factory default: 1-2-3-4-5-6).
- 3 beeps + green LED = valid. Turn handle within 4 seconds.
Change Your Combination (Non-Display)
ALWAYS perform this with the safe door OPEN.
- Press #52 on the keypad.
- Enter your User ID + current combination.
- Enter your User ID + new combination.
- Enter your User ID + new combination again to confirm.
- Press the Return Key (←).
Example: Master (ID 00) changing from 1-2-3-4-5-6 to 6-5-4-3-2-1:
Add a User (Non-Display — Master Only)
Delete a User (Non-Display — Master Only)
Enable/Disable Dual User Mode (Non-Display)
Master Reset (Non-Display)
# Command Quick Reference — 702
| Command | Function |
| #52 | Change your own combination |
| #54 | Add a new user |
| #56 | Delete a user |
| #58 | Master reset (factory reset) |
| #12 | Enable/Disable Dual User Mode (0=Off, 1=On) |
| #14 | Enable/Disable Duress Mode (0=Off, 1=On) |
| #40 | Backlight On/Off (0=Off, 1=On) |
| #42 | Buzzer On/Off (0=Off, 1=On) |
| #44 | Combo length (6–9 digits) |
| Model | LaGard 703 / 703B — High-security multi-lock |
| Display | Yes — 1.28" monochrome OLED display |
| Factory Default | User ID 00 · Combination 1-2-3-4-5-6 |
| Code Length | 6–9 digits (configurable) |
| Users | 30 total — 1 Master (ID 00) + 1 Manager (ID 01) + 28 Users |
| Locks | Up to 2 lock bodies from one keypad |
| Dual User Mode | Yes — requires 2 authorized users to open |
| Time Delay | 0–99 minutes (with 1–60 minute confirmation window) |
| Audit | 500 events — viewable on-screen or via USB |
| Credential Mode | 703B supports Dallas key as second credential |
| Power | Two 9V alkaline batteries |
| Penalty | 5-minute lockout after 4 wrong attempts |
Open the Safe
- Press any key to wake the keypad — OLED display illuminates.
- Enter your User ID (factory Master ID is 00).
- Enter your combination (factory default: 1-2-3-4-5-6).
- If multiple locks are installed, select the lock number to open.
- The screen shows "Open" — turn the handle within 4 seconds.
Change Your Combination
ALWAYS perform this with the safe door OPEN.
- Enter your User ID and current combination to log in.
- From the Main Menu, select "Change Combo".
- "New Combo" appears — enter your new combination.
- Re-enter the new combination to confirm.
- "Success" appears + 3 beeps + green LED.
Add a New User (Master Only)
- Log in with Master ID (00) and Master combination.
- Navigate to Main Menu → Users → Add.
- Enter the User ID to assign.
- Enter an initial combination for the new user.
- Set privileges: Open, Audit, Time Delay Override, Dual User Override.
- 3 beeps + green LED confirms.
Delete a User (Master Only)
- Log in with Master ID (00).
- Navigate to Main Menu → Users → Delete.
- Enter the User ID to delete. Confirm when prompted.
Multi-Lock: Select Which Lock to Open
The 703 can control up to 2 lock bodies from one keypad. After entering a valid ID and combo, the display shows the lock selection screen. Press the corresponding number to open that lock.
Enable/Disable Dual User Mode
- Log in as Master.
- Navigate to Main Menu → System → User Mode.
- Select Single, Dual, or Dual + Mgr.
View Audit Trail
- Log in with a user that has Audit privileges.
- Navigate to Main Menu → Audit.
- Scroll through events on screen, or connect via USB to download to PC using LaGard Software.
Master Reset
- Log in with Master ID (00).
- Navigate to Main Menu → Locks → Reset.
- In a multi-lock system, reset secondary locks first — Lock #1 must be reset last.
- Confirm when prompted. "Success" appears.
| Model | LaGard 705 — Flagship (replaces SmartLinc II) |
| Display | Yes — 1.28" monochrome OLED display |
| Factory Default | User ID 00 · Combination 1-2-3-4-5-6 |
| Code Length | 6–9 digits (configurable) |
| Users | 99 total — 1 Master (ID 00) + 1 Manager (ID 01) + 97 Users |
| Locks | Up to 5 lock bodies from one keypad |
| Dual User Mode | Yes — requires 2 authorized users to open |
| Time Delay | 0–99 minutes (with 1–60 minute confirmation window) |
| Timelock | Yes — programmable schedules via LaGard Software |
| Audit | 6,000 events — viewable on-screen or via USB |
| Bluetooth Fob | Yes — used as second credential (cannot open alone) |
| Power | Two 9V alkaline batteries |
| Penalty | 5-minute lockout after 4 wrong attempts |
Open the Safe
- Press any key to wake the keypad — OLED display illuminates.
- Enter your User ID (factory Master ID is 00).
- Enter your combination (factory default: 1-2-3-4-5-6).
- If a Bluetooth fob is required for your user, present it when prompted.
- If multiple locks are installed, select the lock number to open.
- The screen shows "Open" — turn the handle within 4 seconds.
Change Your Combination
ALWAYS perform this with the safe door OPEN.
- Enter your User ID and current combination to log in.
- From the Main Menu, select "Change Combo".
- "New Combo" appears — enter your new combination.
- Re-enter the new combination to confirm.
- "Success" appears + 3 beeps + green LED.
Add a New User (Master Only)
- Log in with Master ID (00) and Master combination.
- Navigate to Main Menu → Users → Add.
- Enter the User ID to assign.
- Enter an initial combination for the new user.
- Set privileges: Open, Audit, Time Delay Override, Dual User Override, Fob Override.
- If assigning a Bluetooth fob, enroll the fob at the keypad and assign it to the user.
- 3 beeps + green LED confirms.
Delete a User (Master Only)
- Log in with Master ID (00).
- Navigate to Main Menu → Users → Delete.
- Enter the User ID to delete. Confirm when prompted.
Multi-Lock: Select Which Lock to Open
The 705 can control up to 5 lock bodies from one keypad. After entering a valid ID and combo, the display shows the lock selection screen. Press the corresponding number to open that lock.
Timelock (705 Only)
Timelock schedules are programmed through the LaGard Software on a PC, then sent to the keypad via USB. When Timelock is active, the lock can only be opened during scheduled open windows. Only the Master can change time and date settings while Timelock is active.
If a user has Time Delay Override privileges, they can bypass the time delay (but not the Timelock schedule) using their combo or Bluetooth fob credential.
Bluetooth Fob (705 Only)
The 705 supports a Bluetooth fob as a second credential. The fob cannot be used alone to open the lock — it must be paired with a user combination. Fobs are enrolled at the keypad and assigned to specific users through the Users menu.
View Audit Trail
- Log in with a user that has Audit privileges.
- Navigate to Main Menu → Audit.
- Scroll through up to 6,000 events on screen, or download via USB to PC.
Master Reset
- Log in with Master ID (00).
- Navigate to Main Menu → Locks → Reset.
- In a multi-lock system, reset secondary locks first — Lock #1 must be reset last.
- Confirm when prompted. "Success" appears.
Battery Replacement (All Models)
All LaGard 700 Series standard-profile keypads use two 9V alkaline batteries in a slide-out battery tray. Low-profile keypads require an external Battery Box or Power Adapter.
- Press the button on the bottom-right of the keypad to release the battery compartment.
- Slide out the battery tray.
- Replace both 9V batteries with fresh Energizer or Duracell alkaline batteries.
- Slide the battery tray back in until it clicks.
- Test the lock before closing the door.
Low Battery Warning
When batteries are getting low, the keypad will give repeated audio and visual signals during lock operation. On display models, a low battery icon appears on screen. When critically low, you'll hear 3 low beeps with 3 red LED flashes. Replace immediately — if power is lost completely, hold a fresh 9V battery to the external contacts on the keypad face while entering your code.
Wrong Try Penalty
After 4 consecutive incorrect codes, the lock enters a 5-minute lockout. The LED flashes red at 10-second intervals. After the lockout expires, entering 2 more incorrect codes triggers another 5-minute penalty.
Lost Master Combination
If the Master combination is lost and the safe can be opened (by another authorized user or because the door is already open), a LaGard 700 Series Reset Box can be connected directly to the lock body to reset the system. This requires physical access to the lock body inside the safe door. The Reset Box cannot open a locked safe — it only resets combinations when you already have access.
If the safe is locked and no valid codes are available, a locksmith will need to drill the safe to gain access.
Troubleshooting
- No response from keypad: Batteries are dead. Replace both 9V batteries. For low-profile keypads, check the Battery Box or Power Adapter connection.
- 3 red flashes + 3 low beeps: Invalid code. Make sure you're entering the correct User ID first, then the combination. Check that you're not in a penalty lockout (LED flashing every 10 seconds).
- Handle won't turn after valid code: You have 4 seconds to turn the handle. If it still won't open, the bolt work may be binding — contact a safe technician.
- New user can't open the lock: All newly added users must change their initial combination first. This is a 700 Series security requirement.
- "Force Change" prompt: The Master enabled Force Change mode. Follow on-screen prompts or use #52.
- Lock expects a second code: Dual User mode is active — a second user must enter their ID and combo. The Master can disable this through the menu or #12 command.
- Lock won't open during certain hours (705): Timelock is active. The lock can only be opened during scheduled windows.
- Lost combination: If the safe is open, use a LaGard 700 Series Reset Box on the lock body. If locked, a safe technician will need to drill.
Manufacturer Documents
📄 Official dormakaba LaGard 700 Series Resources
Frequently Asked Questions
What is the difference between the LaGard 701, 702, 703, and 705?
All four use the same lock body — the keypad determines the feature level. The 701 is entry-level with 3 users and no display. The 702 supports 10 users and is available with or without a display. The 703 has an OLED display, supports 30 users, and can control up to 2 locks. The 705 is the flagship with 99 users, 5 locks, timelock schedules, Bluetooth fob support, and a 6,000-event audit trail.
What is the default combination on the LaGard 700 Series?
The factory default is User ID 00 (Master) with combination 1-2-3-4-5-6. The Master combination should be changed immediately after installation for security. A Manager user (ID 01) may also be pre-installed with combination 1-2-3-4-5-6.
What are # commands and how do I use them?
The # commands are the programming method for non-display keypads (701 and 702 without display). Instead of navigating a screen menu, you type a # followed by a command number, then your User ID and combination, then any parameters, and finish by pressing the Return Key (← back arrow). For example, #52 is the command to change your combination. Display keypads can also use # commands if preferred.
Do I need a display keypad or can I use the non-display version?
Both work with the same lock body and offer the same core functions. The display keypad (702D, 703, 705) is easier to use because you navigate menus visually. The non-display version (701, 702) uses # commands which are just as fast once you know them, and costs less. For basic open/close and code changes, either works fine. If you need audit viewing, multi-lock management, or time delay configuration, the display models are more convenient.
Can I use my old LaGard keypad with a 700 Series lock?
No. The 700 Series reversed the architecture — the keypad now holds the memory and intelligence, while the lock body is universal. Old LaGard keypads (Basic, 39E, 66E, Supra) are not compatible with 700 Series lock bodies, and 700 Series keypads are not compatible with legacy lock bodies. However, the 700 Series lock body mounts in the same footprint, so upgrading is straightforward.
Will my codes survive a battery change on the 700 Series?
Yes. All combinations, user settings, and audit data are stored in non-volatile memory and are retained indefinitely without power. You will not lose any codes when replacing batteries.
Need More Help?
If these instructions didn't solve your issue, contact the manufacturer directly or call your local locksmith:
Can't reach the manufacturer? Our licensed safe technicians service all LaGard models throughout Brevard County.